From the Word, references tab, click insert citation, -then on the search bar click the Go to Mendeley button, -click the reference to highlight it in your Mendeley library reference list -on the top menu bar the Cite (Send citation to plugin) bu tton appearsKeep sight of your Word document at all times - Mendeley Cite opens as a separate panel in Word alongside your document window, not over it. Keep your document in view as you cite: Mendeley Cite opens as a separate panel in Word alongside your document window, not over it, so your whole document remains visible as you find, select and insert references.Macros used with Microsoft Word to add new functionalities to Mendeley's plugin.Mendeley features: Reference Manager - generate citations and bibliographies in Word and other document create programs PDFs: attach and open PDFs, highlight.-Insert by clicking Ok in the Mendeley search bar 2. Cite without having Mendeley Desktop open or even installed, minimizing potential performance loss.

Mendeley Cite How To Modify The
Macros GAUG_removeHyperlinksForCitations(strTypeOfExecution As String)Removes all hyperlinks generated for the citations from the document and leaves all fields as originally inserted by Mendeley's plugin. See the detailed instructions bellow on how to modify the original macro. If you are happy with your bibliography, just forget about refreshDocument. See the detailed instructions bellow on how to install them.If you are annoyed that Mendeley's plugin changes the font style of the bibliography every time you refresh it, then you need to modify the refreshDocument macro installed by Mendeley's plugin to correct the problem.
WARNING: UNEXPECTED RESULTS IF MANUAL MODIFICATIONS EXIST, BUT VERY FAST. This value CANNOT be used if the square brackets are part of the hyperlinks in the IEEE CSL citation style. Manual modifications to citations and bibliography will remain intact. "RemoveHyperlinks": Removes the bookmarks and hyperlinks from the document.
strStyleForTitleOfBibliography: Specifies the Microsoft Word style used for the title of the bibliography. WARNING: SAFE, BUT VERY SLOW IN LONG DOCUMENTS. Manual modifications to citations and bibliography will also be removed to have a clean environment. "CleanFullEnvironment": Removes the bookmarks and hyperlinks from the document. WARNING: STILL EXPERIMENTAL, BUT FAST. Manual modifications to citations and bibliography will also be removed to have a clean environment.
blnMabEntwickeltSich: The default value False will force the macro to check every section of the document for the bibliography IT IS THE WAY TO GO. The default value is a custom style called “Titre de dernière section” that you may need to create or change. The document MUST follow a particular structure see the description of the flag blnMabEntwickeltSich. It is only used when the flag blnMabEntwickeltSich is set to True.
It MAY not work if you make manual modifications to the citation fields, bibliography or both IEEE and APA CSL citation styles.NOTE: strTypeOfExecution="RemoveHyperlinks" is the way to go it is reliable and fast. In addition to the style, the bibliography MUST also be placed in a section with a title in that style or the macro will not find it.Important: It works ONLY with the IEEE and APA CSL citation styles installed with Mendeley. First, the style specified by strStyleForTitleOfBibliography MUST exist otherwise the macro will throw an error.
This function is also called when creating hyperlinks for IEEE and APA citation styles. Mendeley is slow when undoing changes to citation fields. The execution with the last option may take several minutes use it with caution. If you want to be in the safe side, use strTypeOfExecution="CleanFullEnvironment" which calls Mendeley's functions to do the job. It executes a very light weight version of Mendeley's function Mendeley.undoEdit to remove the hyperlinks and manual modifications from the citations. If previous approach did not work, use strTypeOfExecution="CleanEnvironment" also fast but still considered as EXPERIMENTAL.
The citations must follow the APA CSL citation style. It also creates the hyperlinks for the URLs in the bibliography. GAUG_createHyperlinksForCitationsAPA()Creates the bookmarks in the bibliography and the hyperlinks for the citations in the document. GAUG_cleanFullEnvironment()Wrapper for GAUG_removeHyperlinksForCitations("cleanFullEnvironment"). GAUG_cleanEnvironment()Wrapper for GAUG_removeHyperlinksForCitations("cleanEnvironment").
arrNonDetectedURLs: Specifies the URLs that were not detected, or fully detected, by the regular expression in the bibliography. If the flag is set to False, the macro will not generate the hyperlinks for the URLs in the bibliography. The regular expression used to detect the URLs may not find them all in such case you need to manually specify those that were not detected or fully detected.
It also creates the hyperlinks for the URLs in the bibliography. GAUG_createHyperlinksForCitationsIEEE()Creates the bookmarks in the bibliography and the hyperlinks for the citations in the document. It MAY not work if you make manual modifications to the citation fields, bibliography or APA CSL citation style. See more details in the description of the GAUG_removeHyperlinksForCitations(strTypeOfExecution As String) macro about the type of execution.Requires: GAUG_removeHyperlinksForCitations(strTypeOfExecution As String)Important: It works ONLY with the APA CSL citation style installed with Mendeley. strTypeOfExecution: The default value "RemoveHyperlinks" is the fastest and THE WAY TO GO. The list is only used when the flag blnGenerateHyperlinksForURLs is set to True.